Automatic Sprinkler repair

Automatic Fire Sprinkler Inspection, Repair, Maintenance, and Testing Requirements

Having an automatic fire sprinkler in a commercial building is the prime line of defense whenever a fire breaks out. This makes them a crucial fire safety measure in the building. Automatic fire sprinkler systems can prevent a fire outbreak and keep it minimal while protecting the occupants from harm and saving the property from big losses.

Are you sure that your automatic sprinkler system will work when required? How often the system should be inspected? It is imperative to stay updated on automatic sprinkler repair, testing, and maintenance. Professionals ensure that the systems are in working order by inspecting regularly and also following the testing, repair, and maintenance timelines. While you follow the mandatory automatic sprinkler repairs, testing, and maintenance schedules that have been set by the National Fire Protection Association and local authorities, ensure that you have applied systems that operate as they have been designed to minimize the risk of property damage and loss of life in case there ever be a fire.

Hire Professionals For Scheduled Fire System Inspection and Repairs

It is highly recommended to hire the services of professionals like AHS Fire Protection. Experts at AHS Fire Protection are familiar with the fire system’s scheduled inspection and maintenance. They offer mandatory fire system inspections, testing, repair and maintenance. Other than these, other vital resources are available for all types of fire sprinkler inspection and testing requirements – monthly, quarterly, semi-annually, annually, and other considerations.

How Often Do Automatic Fire Systems Have To Be Inspected?

The adopted codes oblige all commercial, as well as, nonprofit organizations to follow the NFPA 25 different standards when it comes to Inspection, testing, repair and maintenance of Sprinkler fire protection systems. Each of the local services does have additional fire sprinkler inspection, testing and maintenance requirements. Ensure to check with the service for the local codes.

Save lives and Minimize Property Loss

If you notice something wrong with your fire sprinkler during the inspections or suspect anything otherwise, get it in touch with AHS Fire Protection, as quickly as possible for automatic sprinkler repairs.

AHS Fire Protection has a network of professional technicians and skilled contractors with factory certification, training, and licensure who can be there quickly to ensure your automatic sprinkler systems are fully functional and complies with NFPA25 and NFPA 291 standards, requirements and local codes.

Class ll Standpipe Repair – Why Is It Crucial To Have Weekly Repair and Maintenance Checks?

If your facility is multi-story or a relatively large area such as a shopping complex then you would have a standpipe system installed for sure. This water-based fire protection system is a crucial aspect of your structure’s fire and safety design. It supplies water to the building’s sprinkler system, enabling the firefighters to connect the fire hoses directly on the floor in case of a fire breakout.

Standpipes have different types; some of them are dry and require the experts to hook them up to the water supply while others may have water in them – all set to be used. Some of these standpipes have sufficient pressure from the water supply that makes them work automatically, whereas others may need the assistance of a pumper truck.

The Class ll Standpipes operates as a 1.5-inch fire hose connection. It is generally set up in cabinets. These pipes are designed mainly for professional resident use and are laid out in accordance to the hose length. The connection spacing and hose length are planned to reach out all levels of the building. These vales must be examined weekly for leaks, damage, or missing caps.

What To Do?

Considering the Class II Standpipe repair, it is imperative to inspect it weekly for:

  • Signs of leakage or damage
  • Ensure all control vales are properly in place
  • Check around for cap gaskets and dry rot on the hose
  • Check for equipment labels
  • Ensure equipment is easily accessible – it must not be blocked by boxes or other items
  • Gauges on deluge, pre-action, dry valves for standpipes must be regularly checked for normal water and air pressure – automatic hydrants can be examined once a month

Routine Class ll Standpipe Repair  and Maintenance Checks Help Prevent Problems

One of the most common issues found with the Standpipes is related to housekeeping. The standpipes

must be functional by keeping the surrounding valves and pipes painted and cleaned to avert corrosion. To avoid Class II Standpipe repairs, it is recommended to hire professionals to look around for repair and maintenance checks for missing handles/caps, leaking valves and damaged devices – weekly checks can prevent the problem before it even escalates!

The weekly checks help highlight emergency repair and maintenance issues; whereas the semi-annual and annual inspections examine the fire system comprehensively for problems that may go unnoticed during the weekly checks. At the semi-annual inspections, the supervisory signal devices, valve supervisory devices, and alarm devices will be tested. Furthermore, the annual checks examine the main drain, hose storage devices, and hose nozzles.

Hiring professionals like AHS Fire Protection ensure you have proper standpipe testing, repair and maintenance, ensuring all hose connections and valves are fully operational and will not disappoint in the time of need!

Request a Callback

Enter your details in the form and we will call you back.

Error: Contact form not found.